| Availability: | |
|---|---|
| Quantity: | |
The LY-3033 Portable THC Analyzer FID is a professional-grade, field-ready gas detection device built on the industry-leading Flame Ionization Detector (FID) principle, optimized for high-precision VOCs fugitive emission monitoring and leak localization. Designed for industrial clients and environmental regulatory agencies, this FID VOCs Detector delivers rapid, accurate identification of VOC leaks across pipeline valves, discharge ports, and enclosed facility systems, enabling proactive maintenance, ensuring uninterrupted industrial operations, and supporting strict environmental compliance management. With optional PID detection configuration, it adapts to diverse on-site monitoring needs with unmatched flexibility.
This explosion-proof VOCs analyzer holds authoritative explosion-proof certification, allowing safe, compliant operation in high-risk explosive atmospheres, a critical feature for petrochemical and refining facilities.
Equipped with a high-sensitivity, multi-range FID detector and optional PID module, it delivers ultra-low detection limits down to 0.5 ppm, with a response time of <3.5 s to reach 90% of the final reading, ensuring real-time, accurate leak capture.
Featuring a fully molded, lightweight design (<3.1 kg), it supports shoulder or diagonal carrying via an included strap. The explosion-proof display controller with wireless control functionality enables simple, one-handed operation in complex field environments.
Built-in full self-test function automatically detects instrument status and provides fault prompts for simplified maintenance. It also supports seamless integration with the optional Lonying LDAR leakage and repair data platform, realizing full-process systematic management of detection workflows.
The LY-3033 Portable THC Analyzer FID is fully compliant with the latest environmental monitoring standards and regulations issued by the Ministry of Ecology and Environment of China, as well as relevant international standards. It has obtained the China Environmental Protection Product Certification (CPA) and authoritative explosion-proof certification, ensuring its data validity and legal compliance for enterprise environmental reporting and regulatory law enforcement.
Main Parameter | Parameter Range |
|---|---|
Measuring Range | FID: (1.0 ~ 50,000) ppm methane<br>PID: (0.5 ~ 2,000) ppm isobutylene |
Response Time | FID: ≤ 3.5 s to reach 90% of final value using 10,000 ppm methane<br>PID: ≤ 3.5 s to reach 90% of final value using 500 ppm isobutylene |
Repeatability | FID: ±2% at 500 ppm methane<br>PID: ±2% at 100 ppm isobutylene |
Accuracy | FID: ±10% of reading or ±0.1 ppm, whichever is greater, from 1.0 to 10,000 ppm<br>PID: ±20% of reading or ±0.5 ppm, whichever is greater, from 0.5 to 2,000 ppm |
Linearity Range | Full scale |
Warm-up Time | < 20 min |
Lower Detection Limit | FID: 0.5 ppm methane<br>PID: 0.5 ppm isobutylene |
Operating Conditions | Ambient temperature: (-10 ~ 50) °C; Relative humidity: ≤ 90%; Atmospheric pressure: (86~106) kPa |
Sampling Flow Rate | Approx. 0.8 L/min |
Gas Duration | ≥ 10 h |
Battery Life | ≥ 10 h |
Communication | Bluetooth or Wi-Fi |
Power Consumption | < 4 W |
Dimensions (L×W×H) | 258 mm × 191 mm × 82 mm |
Weight | < 3.1 kg |
Routine inspection of pipelines, valves, and storage tanks for industrial leak detection, tracing VOC leak sources to prevent safety accidents and ensure workplace safety.
Rapid screening of VOC-contaminated areas at soil and groundwater remediation sites, real-time monitoring of remediation progress, and accurate definition of pollution boundaries.
Quick identification of VOC concentration and dispersion range at leak, fire, or other environmental accident scenes, providing real-time data support for emergency decision-making and personnel evacuation.
Monitoring VOC exposure levels in workers’ breathing zones, assessing occupational health risks, and ensuring compliance with indoor and workplace air quality standards.
As a trusted provider of professional environmental monitoring solutions for industrial clients, Lonying delivers rigorously certified, field-proven equipment with long maintenance cycles and intuitive operation. We provide comprehensive pre-sales consultation, customized on-site training, complete operation and maintenance manuals, and full after-sales technical support to help enterprise users achieve efficient, compliant environmental monitoring and management.
The device adopts the industry-standard Flame Ionization Detector (FID) principle for total hydrocarbon and VOC detection, with an optional Photoionization Detector (PID) module to expand detection capabilities for diverse industrial scenarios.
Yes. The LY-3033 Portable THC Analyzer FID has obtained authoritative explosion-proof certification, ensuring safe and stable operation in environments with explosion-proof requirements.
The analyzer supports Bluetooth and Wi-Fi communication, and can be seamlessly connected to the optional Lonying LDAR leakage and repair data platform, realizing full systematization of the detection process and data traceability.
Copyright© 2026 Qingdao Laoying Haina Opto-electronic Environmental Protection Group Co., Ltd. All Rights Reserved. Sitemap | Privacy Policy